LK166
Home >> Supply >> OMRON CS1D-BC052 Specifications: Applicable systems, OMRON CS1D-BC052
Search
Information sort

OMRON CS1D-BC052 Specifications: Applicable systems, OMRON CS1D-BC052


Supply voltage: 100 to 240 V AC, 50/60 Hz (wide range).
Operating voltage range: 85 to 265 V AC.
Output capacity: 5 V DC: 3.6 A(18 W).C200H A Backplane I/O Mounting Bracket For 8 Slots C200H-ATTA3.
Name: CS1D CPU Backplane.
Specifications: Applicable systems,
Duplex CPU, Single I/O Expansion System only;
Number of Power Supply Units, 2 Units max CS1D-BC0552.
(for duplex operation);
Number of I/O Units, 5 Units max.
Current consumption: 5V system, 0.55A;
26V system, -- CS1D-BC052.
Standards: UC1, N, L, CE.
Redundant CPU Units , Power Supply Units ,
Communications Units ,
and Expansion I/O Cables. Model: C500-CE401.
Solder pin connector cover 40PModel: CPM2C-20CDT1M-D. CPU Unit: Units with 20 I/O points.
2 MIL connectors.
Inputs: 12 inputs CS1D-BC052.
Outputs: 8 outputs.
Input type: 24 VDC.
Output type: sourcing transistor.
Internal clock: --.General Information
The C200HS-SLK12 SYSMAC LINK fiber-optic module connects the PLC to the SYSMAC
LINK fiber-optic token bus peer-to-peer communications network. An external power supply option provides direct pass-through communications in case of modulModel: CPM2C-10CDTC-D OMRON CS1D-BC052. CPU Unit: Units with 10 I/O points.
2 Fujitsu connectors.
Inputs: 6 inputs.
Outputs: 4 outputs.
Input type: 24 VDC.
Output type: sinking transistor.
Internal clock: -- OMRON CS1D-BC052.Specifications: 8 Kwords with clock.Model: C200H-BC101-V2.
No. of I/O slots: 10 slots.Name: Heat/Cool Temperature Control Module.
Model: C200H-TV003.
Sensor: Thermocouple: R, S, K, J, T, E, B, N, L, U.
Control output: Current output(transistor output used for cooling outputs) OMRON CS1D-BC052.No. of I/O slots: 8 slots.C500-DA/3G2A5-DA Special I/O Unit Analog Output C500-DA005(3G2A5-DA005).
Output: 2 pts.
Specification: -5~+5V.Name: SYSMAC LINK Module.
Model: C200HW-SLK24.
Communications method: N: N token bus.
Transmission method: Manchester code, base band.
Transmission path: Bus.
Weight: 400 g max.I/O points: 256 pts.
Program capacity(words): 7.2 K.
DM capacity (words): 6 K.
RS-232C port: YES.
Pulse I/O: YES.Name: Two-tier Screw Terminal Block.
Specifications: Inputs/Outputs;
8 inputs/8 outputs; PNP.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
> Seven-segment Display on the Gateway Unit,
helps to detect errors on site CS1D-BC052.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error.

Related supply information