MITSUBISHI FA-LEB16XY
Input supply voltage: DC24V.
Input frequency: -.
Input maximum apparent power: -.
Maximum input power: 50.
Rated output current (DC5V): 6.5A.
Rated output current (DC24V): -.
IQ-R MELSEC series consists of CPU module, power module, substrate module, input and output module, intelligent function module and so on .
For the entire system, the substrate module can be expanded to 7 levels, up to 64 modules can be installed,
Therefore, large scale system can be constructed FA-LEB16XY In addition, by using the RQ extended substrate module,
The sea can also effectively use the MELSEC-Q series of modules of the asset. Output points: 24 points.
Voltage: DC24V/AC240V, 2A/1 point, 8A/1 public end FA-LEB16XY.
Output type: relay output .
Response time: 12ms.
8 point /1 a public side.
38 point terminal station.
CE certification.
The number of I/O thyristor DC motor control required tube DC motor speed control system is the main form of DC speed regulation,
The thyristor rectifier unit is used to supply power to the DC motor.
PLC control of the DC drive system, the input of the PLC in addition to the main signal outside the signal,
We need to consider the switching signal, the fault signal transmission device, brake signal and fan fault signal FA-LEB16XY.
The output of the PLC mainly consider the speed command signal positive 1~3 level, 1~3 level, allowing reverse switching signal and brake open signal etc..
In general, a reversible DC drive system controlled by PLC is approximately 12 input points and 8 output points,
An irreversible DC drive system requires 9 inputs and 6 output points.
MITSUBISHI PLC is the main product in the production of MITSUBISHI motor in Dalian.
It uses a kind of programmable memory for its internal storage procedures,
Execute logic operation, sequence control, timing, counting and arithmetic operations, user oriented instruction,
And through digital or analog input / output control of various types of machinery or production process.
Control solenoid valve required I/O points by the action principle of the solenoidd valve can be known,
A single coil solenoid valve with PLC control to 2 input and 1 output,
A double coil solenoid valve requires 3 inputs and 2 outputs,
A button needs an input; a light sensitive switch needs 4 or 2 inputs,
A signal lamp needs 1 outtput, band switch,
Several bands are required for several inputs,
In general, a variety of position switches are required to take up 2 input points FA-LEB16XY FA-LEB16XY.
FA-LEB16XY Operation manual / Instructions / Catalog download link: /searchDownload.html?Search=FA-LEB16XY&select=5


...more relevant model market price >>>>
Related products
MITSUBISHI
Conversion module
FA-LEB32XY-3
MITSUBISHI Conversion module FA-LEB32XY-3
Convert connectors to e-CON.
MITSUBISHI
Conversion module
FA-TB16XY1N
MITSUBISHI Conversion module FA-TB16XY1N
Convert connector to screw relay termina
MITSUBISHI
Conversion module
FA-TB16XYPN
MITSUBISHI Conversion module FA-TB16XYPN
Can e used as a screw relay terminal.
MITSUBISHI
Conversion module
FA-CB16XY2
MITSUBISHI Conversion module FA-CB16XY2
Convert connectors to fast connectors. A