LK166
Home >> Price >> MITSUBISHI >> FR-BU2-15K
Brand sort

MITSUBISHI FR-BU2-15K

Country: JAPAN
Name: Brake unit
Model: FR-BU2-15K
Price: 0
MITSUBISHI FR-BU2-15K
Input points: 32 points.
Input voltage and current: 3/7mA DC12/24V.
Input response time: 10ms.
16 point /1 a public side.
Positive pole sharing.
Output points: 24 points.
Output voltage: DC24V/AC240V, 2A/1 point, 5A/1 common end.
Output response time: 12ms.
Output type: relay output.
8 point /1 a public side .
With the surge absorber.
Control solenoid valve required I/O points by the action principle of the solenoid valve can be known,
A single coil solenoid valve with PLC control to 2 input and 1 output,
A double coil solenoid valve requires 3 inputs and 2 outputs,
A button needs an input; a light sensitive switch needs 4 or 2 inputs,
A signal lamp needs 1 output, band switch,
Several bands are required for several inputs,
In general, a variety of position switches are required to take up 2 input points FR-BU2-15K
MITSUBISHI PLC is the main product in the production of MITSUBISHI motor in Dalian.
It uses a kind of programmable memory for its internal storage procedures,
Execute logic operation, sequence control, timing, counting and arithmetic operations, user oriented instruction,
And through digital or analog input / output control of various types of machinery or production process FR-BU2-15K.
The number of I/O thyristor DC motor control required tube DC motor speed control system is the main form of DC speed regulation,
The thyristor rectifier unit is used to supply power to the DC motor.
PLC control of the DC drive system, the input of the PLC in addition to the main signal outside the signal,
We need to consider the switching signal, the fault signal transmission device, brake signal and fan fault signal.
The output of the PLC mainly consider the speed command signal positive 1~3 level, 1~3 level, allowing reverse switching signal and brake open signal etc..
In general, a reversible DC drive system controlled by PLC is approximately 12 input points and 8 output points,
An irreversible DC drive system requires 9 inputs and 6 output points. Input and output points: 2048 points.
Input / output data points: 8192 points.
Program capacity: 92k.
Basic command processing speed (LD command) S:0.15.
The length of time required to execute the instruction, the length of the user''s program, the type of instruction, and the speed of the CPU execution are very significant,
Generally, a scanning process, the fault diagnosis time,
Communication time, input sampling and output refresh time is less,
The execution time is accounted for the vast majority of.
The photoelectric coupler is composed of two luminous two extreme tubes and a photoelectric transistor.
Light emitting diode two: the input of a photo coupler and the change of electrical signal,
The light signal is generated by the light emitting diode, which is the same as the input signal.
The working process of the input interface circuit: when the switch is closed, the diode light,
The transistor is then guided to the internal circuit and input signal under the irradiation of the light.
When the switch is off, the diode does not emit light, and the transistor is not on the way. Internal circuit input signal.
It is through the input interface circuit to the external switch signal into PLC internal can accept the digital signal.
Photoelectric three levels: in the light of the light signal conduction, the degree of light signal and the intensity of the light signal.
The output signal has a linear relationship with the input signal in the linear operating region of the photoelectric coupler. FR-BU2-15K.
User program storage cappacity: it is a measure of how much the user application can store the number of indicators .
Usually in words or K words as units. 16 bit binary number is a word,
Every 1024 words are 1K words. PLC to store instructions and data in words.
General lloggical operation instructions each account for 1 words FR-BU2-15K. Timer / counter,
Shift instruction accounted for 2 words. Data operation instructions for 2~4.

FR-BU2-15K Operation manual / Instructions / Catalog download link: /searchDownload.html?Search=FR-BU2-15K&select=5


...more relevant model market price >>>>
Related products
MITSUBISHI
Brake unit
FR-BU2-1.5K
MITSUBISHI Brake unit FR-BU2-1.5K
Power: 1.5kw. Voltage: 200V. Purpose: hi
MITSUBISHI
Brake unit
FR-BU2-H55K
MITSUBISHI Brake unit FR-BU2-H55K
Power: 55kw. Voltage: 400V. Purpose: hig
MITSUBISHI
Brake unit
FR-BU2-15K
MITSUBISHI Brake unit FR-BU2-15K
Power: 15kw. Voltage: 200V. Purpose: hig
MITSUBISHI
Brake unit
FR-BU2-30K
MITSUBISHI Brake unit FR-BU2-30K
Power: 30kw. Voltage: 200V. Purpose: hig