OMRON D4SL-N3NDA-DN

No PHOTO
Brand: OMRON
Country: JAPAN
Name:
Market price: U.S.$ 308.73
(The following are the market open price not sales price!)
OMRON D4SL-N3NDA-DN
Actuator: Adjustable roller lever, form lock (metal lever, resin roller).
Conduit size: 2-conduit; M20.
Built-in switch mechanism: 2NC/1NO (Slow-action).
Popular Safety Limit Switches.
Providing a Full Lineup Conforming to,
International Standards.
Lineup includes models with 1NC/1NO, 2NC, 2NC/1NO and,
3NC contact forms .
(Slow-action models with MBB contacts are available D4SL-N3NDA-DN. )
M12-connector models are also available, saving on labor and,
simplifying replacement D4SL-N3NDA-DN
Standardized gold-clad contacts provide high contact reliability.
Can be used with both standard loads and microloads.
Conforms to EN115-1, EN81-1, and EN81-2 (slow-action models only) D4SL-N3NDA-DN.
Certified standards: UL, EN (TÜV), and CCC . Appearance: Round/Full-guard type LED lighting,
(without Voltage Reduction Unit) A22L-G.
Output: SPST-NC + SPST-NC.
Lighting: LED.
Operating voltage: 24 VAC/VDC.
Operation: Alternate operation (self-holding).
Illumination color: R (red); Y (yellow); G (green); W (white); A (blue).
Install in 22-dia. or 25-dia. Panel Cutout.
(When Using a Ring) D4SL-N3NDA-DN.
Lever for easily mounting and removing the Switch Unit .
Increase wiring efficiency with three-row mounting of Switch Blocks.
Finger protection mechanism on Switch Unit provided as a standard feature.
Use 25-dia. ring to install in 25-dia. panel cutouts.
Mounted using either open-type (fork-type) or closed-type.
(round-type) crimp terminals.
IP65 oil resistance (non-lighted models).
IP65 (lighted models). Time specification: Instantaneous type.
Current setting range: 50 to 160 A.
Operating voltage: 200/220/240 VAC.
Resetting method: Automatic (See note.).
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase.
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked eassily because operation time,
is indicated from the start of operation D4SL-N3NDA-DN.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, annd load conditions D4SL-N3NDA-DN. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
before using the K2CM.
D4SL-N3NDA-DN Operation manual / Instructions / Catalog download link: /searchDownload.html?Search=D4SL-N3NDA-DN&select=5