LK166
Home >> Products >> MITSUBISHI >> CC-Link module >> CC-Link analog module >> AJ65SBT-64AD Analog input module MITSUBISHI AJ65SBT-64AD

AJ65SBT-64AD Analog input module MITSUBISHI AJ65SBT-64AD

Brand: MITSUBISHI
Name: Analog input module
Model: AJ65SBT-64AD
Screw terminal table type.
Voltage / current input module.
Number of channels: 4 channels.
Number of stations: 1 stops.
Station type: remote equipment station.
MITSUBISHI PLC hardware implementation
Hardware implementation is mainly for the control cabinet and other hardware design and field construction.
Design control cabinet and the operating table and other parts of the electrical wiring diagram and wiring diagram.
Electrical interconnection diagram of each part of the design system.
According to the construction drawings of the site wiring, and carry out a detailed inspection.
Because the program design and hardware implementation can be carried out at the same time,
So the design cycle of the MITSUBISHI PLC control system can be greatly reduced.
MITSUBISHI PLC online debugging.
On-line debugging is the process that will through the simulation debugging to further carry on the on-line unification to adjust.
On-line debugging process should be step by step,
From MITSUBISHI PLC only connected to the input device, and then connect the output device, and then connect to the actual load and so on and so on step by step.
If you do not meet the requirements, the hardware and procedures for adjustment.
Usually only need to modify the part of the program can be.

Output type: transistor output, source.
Output points: 16 points.
OFF leakage current: 0.1mA.
Output protection function.
Rated load voltage / current: DC24V/DC24V/0.1A.
External connection: 3 wire.
Sensor connector type (E-CON type).
Using industry standard E-CON type.
Simple wiring through sensor connector MITSUBISHI AJ65SBT-64AD.
When installing the module can choose to use the DIN guide rail or screw mounting AJ65SBT-64AD
3 wire sensor input. Input voltage rating: AC100/120/230/240V
External connection mode: module power supply: Terminal 3 pin (M3 screw), communication line / module power supply unit.
Dedicated power supply for CC-LINK/LT system with built-in 2A power supply. Input type: DC input, positive common end.
Input points: 8 points MITSUBISHI AJ65SBT-64AD.
Enter the response time: 0.2ms the following.
Rated input voltage / current: DC24V/5mA.
Output form: transistor output, leakage type.
Output points: 8 points.
OFF leakage current: 0.25mA.
Output protection function.
Rated load voltage / current: DC24V/0.5A.
External connection: 1 line /1 line type.
According to the external connection mode and the external equipment input and output specifications,
Choose from a rich product lineup MITSUBISHI AJ65SBT-64AD.
Finger protection through the upper part of the terminal,
The human body will not be exposed to live parts,
Therefore, the terminal station type remote I/O module can be directly mounted to the machine tool AJ65SBT-64AD MITSUBISHI. Input type: DC input, positive public end / negative public end.
Input points: 8 points.
Input response time: 0 AJ65SBT-64AD MITSUBISHI. 5ms below /1.5ms.
Rated input voltage / current: DC24V/4mA.
External connection: 2 wire.
Spring clip terminal.
Do not need to re tighten, suitable for wire specifications for 0.3~1.5MM square.
Terminal block is 2 piece structure.
An input module shared by the common terminal of the positive and negative AJ65SBT-64AD MITSUBISHI.
The 8 point of the output module is appended to the source type.
Can be installed along the 6 direction. Input type: DC input, positive / negative public end.
Input points: 8 points.
Enter the response time: 1.5ms the following.
Rated input voltage / current: DC24V/7mA.
Output form: relay output.
Output points: 8 points.
OFF leakage current: -.
Output protection function: No.
Rated load voltage / current: DC24V/AC240V/2A.
External connnection: 3 line /2 line type AJ65SBT-64AD.
According to the external connection mode and the external equipment input and output specifications,
Choose from a rich product lineup.
Finger protection through the upper part of the terminal,,
The human body will not be exposed to live parts,
Therefore, the terminal station type remote I/O module can be directly mounted to the machine tool MITSUBISHI AJ65SBT-64AD.


...More relevant models >>>>