Brand: OMRON
Name: CJ-series Input Units
Model: CJ1W-ID232
Unit type: CJ1 Basic I/O Units.
Product name: DC Input Units.
Specifications: I/O points, 32 inputs;
Input voltage and current: 24 VDC, 4.1 mA;
Commons, 16 points, 1 common; External connection,
MIL connector; No. of words allocated, 2 word.
Current consumption: 5V, 0.09A; 24V, --.
Standards: UC1, N, L, CE.
A Wide Range of Basic Input,
Units for High Speed Input and,
Different Applications.
Receive ON/OFF signals from external,
devices into the PLC System to update,
I/O memory in the CPU Unit.
New high-speed input models CJ1W-ID212 and,
CJ1W-ID233 are now available. These units can,
help to increase system throughput.

Type: CJ1 Special I/O Unit.
Connected ID System: V680 Series; 2 Heads.
External power supply: --.
No. of unit numbers used: 2 unit number.
Current consumption: 5V, 0.32A;
24V, 0.26A; External, --.
Communication Unit Dedicated for RFID V680,
Allowing Direct Connection to OMRON PLC CJ/
CS/NJ-series OMRON CJ1W-ID232.
Communication unit for connecting RFID V680-series,
which can be used around the world, directly to PLC CJ1W-ID232
Allows batch transfer of data up to 32 kbytes. Unit classification: CJ1 Special I/O Units.
Product name: Temperature Control Units.
Specifications; No. of loops: 2 loops,
heater burnout detection function;
Temperature sensor inputs: Platinum ,
resistance thermometer input(JPt100, Pt100);
Control outputs: Open collector,
NPN outputs (pulses) OMRON CJ1W-ID232.
No. of unit numbers allocated: 2.
Current consumption: 5V, 0.25A; 24V, --.
Standards: UC1, N, L, CE.
A Single Unit Performing All the Functions of,
4 Temperature Controllers.
A Special I/O Unit with direct input,
of thermocouple or resistance thermometer,
PID control with 2 degrees of freedom,
and open collector output OMRON CJ1W-ID232. Unit type: CJ1 Basic I/O Units.
Product name: Triac Output Unit.
Specifications: Output type , --;
I/O points, 8 inputs;
Maximum switching capacity, 250VAC, 0.6A;
Commons, 8 points, 1 common;
External connection, Removable terminal block CJ1W-ID232 OMRON.
No. of words allocated: 1 word.
Current consumption: 5V, 0.22A; 24V, --.
Standards: UC1, N, L, CE.
A Wide Range of Basic Output,
Units for High Speed Output,
and Different Applications CJ1W-ID232 OMRON.
These Output Units receive the ,
results of output instructions ,
from the CPU Unit and perform ON/OFF,
control for external devices.
High-speed Output models CJ1W-OD213 and,
CJ1W-OD234 can help to increase system.
throughput CJ1W-ID232 OMRON. I/O capacity/Mountable Units(Expansion Racks): 1, 280 points/40 Units (3 Expansion Racks max.).
Program capacity: 60K steps.
Data memory capacity: 128K words(DM: 32K words, EM: 32K words × 1 bank).Unit type: CJ1 Basic I/O Units.
name: B7A Interface Units.
Specifications: I/O points, 64 inputs;
External connection, Removable terminal block.
No. of words allocated: 4 words.
Current consumption: 5V, 0.07A; 24V, --.
Standards: UC1, CE.
It traansmits 16 points of I/O signals per,
word with a pair of cables CJ1W-ID232.
Easy and minimized wiring effort,
The B7A Interface Unit and B7A Link Terminal,
can be used in the same way as a standard,
Basic I/O Unit and I/O Terminal withouut,
any need to worry about communications OMRON CJ1W-ID232.
This characteristic reduces the wiring,
when using more than one relatively remote,
sensor or actuator.


...More relevant models >>>>