Brand: OMRON
Name: Programmable Controllers
Model: CS1W-OD232
Unit type: CS1 Basic I/O Units.
Product name: Relay Output Units.
Specifications:24 VDC, 0.5 A,
32 outputs; Sourcing.
Mountable Racks: CPU Rack, CS1W-BC,
@@3, Yes, @@2, Yes;
C200HX/HG/HE Expansion I/O Rack, No.
CS1 Expansion Rack, CS1W-BI,
@@3, Yes, @@2, Yes;
CS1 Long distance Expansion Rack, Yes;
SYSMAC BUS Slave Rack, No.
Words required: 2 words.
Current consumption: 5V system, 0.27A;
26 V system, --.
Standards: U, C, N, L, CE.
Multi-application Controllers:
From High-performance Machine C,
Highly Reliable Process Control.

Unit type: CS1 Special I/O Units.
Product name: Analog Input Unit (100 mV).
Input points : 8 inputs.
Signal range: 0 to 100 mV, ±100 mV.
Conversion speed (resolution):
200ms/8 inputs.
Externa connection: Removable erminal block.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.15A; 26V, 0 OMRON CS1W-OD232. 08A.
Standards: UC1, CE.
Provides the functionality of isolators,
power supplies, signal converters,
and other devices CS1W-OD232
The Analog Input Unit converts analog,
input signals such as 1 to 5 V or 4 to 20mA,
into digital values, and takes the values,
scaled in industrial units, and transfers,
it to the CPU Unit as the process value.
Because of this, no ladder program is required,
at the CPU Unit for scaling OMRON CS1W-OD232.
The Analog Output Unit converts analog output set,
values from the CPU Unit to analog output signals,
such as 4 to 20 mA or 1 to 5 V, and outputs them.
The built-in functions, such as measurement value,
alarms, rate-of-change calculations, and square roots,
have enabled major savings in cost and space compared,
with previous systems.
High-resolution Models and 8-point Input Models are,
also available OMRON CS1W-OD232.
By combining the Units, logging/monitoring.
systems can be constructed,
or the Units can be used together with LCBs/LCUs,
to construct complete process control systems CS1W-OD232 OMRON.
Parameters can be easily displayed and set in an,
easy-to-understand form without special tools. Name: CS1D CPU Backplane.
Specifications: Applicable systems,
Single CPU System only;
Number of Power Supply Units, 2 Units max CS1W-OD232 OMRON.
(for duplex operation);
Number of I/O Units, 8 slots max.
Current consumption: 5V system, 0.17A;
26V system, --.
Standards: UC1, N, L, CE.
Redundant CPU Units , Power Supply Units ,
Communications Units ,
and Expansion I/O Cables CS1W-OD232 OMRON. Unit type: CS1 Special analog I/O Units.
Product name: Analog Output Units.
Specifications: I/O points, 8 outputs;
Signal range selection,
Set separately for each input;
Signal range, 1 to 5 V, 0 to 5 V,
0 to 10 V, -10 V to 10 V, 4 to 20 mA;
Resolution, 1/4000 ;
Conversion speed, 1 s/point CS1W-OD232.
Externa connection, Removable erminal block.
Current consumption: 5V, 0.13A; 26V, 0.18A.
Standards: UC1, N, CE.
For Various Analog I/Os.
Annalog Input Units for converting,
analog input signals into binary data OMRON CS1W-OD232.
Analog Output Units for converting ,
binary data into analog output signals.