LK166
Home >> Products >> OMRON >> Master slave station products >> DeviceNet >> DRT2-TS04P OMRON Temperature Input Terminals

DRT2-TS04P OMRON Temperature Input Terminals

Brand: OMRON
Name: Temperature Input Terminals
Model: DRT2-TS04P
Input type: Platinum-resistance thermometer input.
I/O points: 4 inputs allocated 4 input words at the Master Unit,
(8 input words allocated when 1/100 display mode is selected).
Temperature Input Terminal with Smart Functionality.
The Temperature Input Terminal can be used with almost the same functionality as a.
Analog Input Terminal, such as with scaling and comparator functions.
Enhanced performance is provided with functionality specific to the Temperature,
Input Terminal, such as the recording the operating time in a preset temperature,
range and temperature difference detection between input channels.

I/O classification: Output.
Internal I/O circuit common: NPN (- common).
I/O points: 16.
Rated voltage: 24 VDC.
I/O rated voltage: 24 VDC.
Long-distance Communications Supported by SRT2 Models,
(Long-distance/High-speed Communications Selection).
Ultra-compact at 80 x 48 x 50 (W x H x D) mm for,
4-point and 8-point terminals and 105 x 48 x 50,
(W x H x D) mm for 16-point terminals DRT2-TS04P OMRON DRT2-TS04P
Two independent power supplies can be used,
because the I/O terminals are insulated from the internal circuits.
DIN track mounting and screw mounting are both supported.
Specifications: I/O;
NPN (input: + common, output: - common);
Input: 8 points/Output: 8 points.
I/O connections: M3 Screw terminals DRT2-TS04P OMRON.
Rated internal circuit power supply voltage:
Supplied from the communications connector.
Rated I/O power supply voltage: 24 VDC.
Allows I/O Expansion with Transistor Terminals.
Wide variety of data, such as maintenance system data,
can be collected without affecting the productivity,
of the control system.
Valuable information can be collected,
and managed through the network, including information,
on the communications power supply DRT2-TS04P OMRON.
voltage levels, Unit wear and tear,
and equipment operating information.
Expansion via Expansion I/O Units.
With no communications baud rate settings,
required and detachable terminal blocks,
maintenance is easier. Unit: High-density connector model.
I/O classification: Digital output.
Internal I/O common: PNP (+ common).
I/O points: 32.
I/O connections: Fujitsu connector.
Power supplyvoltage: 24 VDC.
I/O specification: 0.5 A, DC/transistor.
Digital I/O Units Compatible with MULTIPLE I/O TERMINAL,
Terminal block, connector, and high-density connector,
models are available.
The circuit block of the terminal block model can be,
mounted or dismounted for eaase of maintenance without,
disconnecting the wires DRT2-TS04P.
DIN track mounting. I/O classification: Relay output.
I/O points: 16.
I/O connections: M3 terminal block.
Power supply voltage: 24 VDC.
I/O specification: 2 A, SPST-NO.
Relay Outtput Unit Compatible with MULTIPLE I/O TERMINAL DRT2-TS04P.
8- and 16-point relay output models are available.
Equipped with 8-point SSRs.
DIN track mounting.


...More relevant models >>>>