LK166
Home >> Products >> MITSUBISHI >> L series PLC >> FA products >> FA-TB1L32XY Conversion module MITSUBISHI FA-TB1L32XY

FA-TB1L32XY Conversion module MITSUBISHI FA-TB1L32XY

Brand: MITSUBISHI
Name: Conversion module
Model: FA-TB1L32XY
The connector is converted to a screw relay terminal.

"Universal output function: source type.
Program capacity: 260K step.
Basic operations processing speed: 9.5ns.
Communication interface: USB/Ethernet (built-in CC-Link function).
Program capacity: 20K step.
Control mode: stored procedure repeated operation.
Input / output points: 4096 points.
End cap MITSUBISHI FA-TB1L32XY.
High precision PWM control of the highest 200kHz.
In the PWM output mode, by setting the ON time and cycle time,
The duty cycle can be changed, and the minimum cycle time is 5 s FA-TB1L32XY
In addition to lighting dimming control, simple motor control and heater control,
Can also be used to require high resolution detection equipment, such as a wide range of oscillators.
CPU built-in functions can be easily set through programming tools MITSUBISHI FA-TB1L32XY.
The built-in I/O function settings can be easily carried out through the parameters of the programming tool.
5 s units can be used for high precision workpiece measurement in pulse measurement mode,
Can be used with a minimum of 5 s units of the input signal of the ON/OFF time (the shortest 200 s) for high precision measurement.
For example, after measuring the ON time of the sensor input,
The "moving speed" and "length" of the workpiece can be accurately calculated " MITSUBISHI FA-TB1L32XY. "Can be isolated from the output of the programmable controller, the a/b/c contact relay, SSR, Tr output.Convert connector to screw relay terminal FA-TB1L32XY MITSUBISHI.
According to the location of the connection equipment distribution module. Can be used as a screw relay terminal.Can be isolated to obtain DC24/48/100V, AC100/200V input signal FA-TB1L32XY MITSUBISHI. Number of input channels: 8ch.
Input voltage: DC - 10 ~ 10V.
Conversion speed: 1ms/ch.
Resolution: 1/16000.
By shifting the function easily when the system starts to fine tune the movement function.
Shift the set value to (shift to) the function of the digital output value FA-TB1L32XY MITSUBISHI.
If you change the conversion value, the value is reflected in real time to the value of the scale (numeric value),
Can easily complete the fine-tuning of the system startup.
Extended detection method based on usage
Anomaly detection and extension of input signal
The detection method of the abnormal detection function of the input signal can be extended to detect the abnormal detection fuunction of the input signal which is outside the range of the set range FA-TB1L32XY.
For the detection of the lower limit or the upper limit of the input signal abnormality, or when the detection of the broken line is performed.
Enter rannge extension
Range of scalable input range MITSUBISHI FA-TB1L32XY.
Combined with the abnormal detection function of the input signal, the broken line can be easily detected.


...More relevant models >>>>