LK166
Home >> Products >> MITSUBISHI >> Inverter >> FR-A800 series inverter >> FR-A820 inverter 3 phase 200V >> FR-A820-90K-1(FR-A820-04750-2-60) | MITSUBISHI FR-A820-90K-1(FR-A820-04750-2-60) Three phase 200V grade frequency converter

FR-A820-90K-1(FR-A820-04750-2-60) | MITSUBISHI FR-A820-90K-1(FR-A820-04750-2-60) Three phase 200V grade frequency converter

Brand: MITSUBISHI
Name: Three phase 200V grade frequency converter
Model: FR-A820-90K-1(FR-A820-04750-2-60)
MITSUBISHI inverter series: FR-A820.
Voltage level: three phase 200V.
Power: 90kw.
SLD converter rated current: 475A.
Structure and function: Standard model.
Type: CA.
Substrate coating: have.
Parameters can be selected by 4 different rated current and different overload rating (SLD (ultra light load) rated, LD (light load) rating, ND (general load) rating, HD (weight).
Type load) for selection.
You can choose the most suitable frequency converter for use; and by selecting a transducer with a SLD or LD rated level,
Be able to reduce the size of the device (compared with the FR-A700 series, to reduce the volume of equipment).
For applications that require high torque at low speeds, the HD rating is the most suitable.
The controller is used to control and monitor the frequency converter through the network.
Standard corresponding RS-485 communication (MITSUBISHI converter protocol, Modbus-RTU protocol) data transmission speed up to 115200bps.

MITSUBISHI inverter FR-E720 series.
Voltage level: 3 phase 200V.
Frequency converter capacity: 1.5KW.
In order to ensure the reliability of production, all production machinery in the design of power with drive, there is a certain amount of surplus.
When the motor can not run under full load, in addition to meet the requirements of power driven,
The surplus torque increases the active power consumption, resulting in the waste of electric energy MITSUBISHI FR-A820-90K-1(FR-A820-04750-2-60) FR-A820-90K-1(FR-A820-04750-2-60)
Speed control method of fan and pump equipment traditional by regulating the entrance or exit of the baffle, valve opening to regulate air flow and water flow
, the input power is large, and a large amount of energy consumption in the baffle, the valve in the process of closure MITSUBISHI FR-A820-90K-1(FR-A820-04750-2-60).
When using variable frequency control, if the flow rate is reduced, the speed of the pump or fan can be reduced to meet the requirements. Length: 1 meters.
Operation panel or parameter unit connection line. MITSUBISHI inverter FR-A720 series.
Voltage level: 3 phase 200V.
Frequency converter capacity: 2.2KW.
Inverter output for the PWM wave, containing more harmonic MITSUBISHI FR-A820-90K-1(FR-A820-04750-2-60).
Frequency conversion power sensor through the input voltage and current signals to exchange sampling,
Sampling value through cable, optical fiber and other transmission systems and digital input frequency conversion power analyzer,
The sampling value of the voltage and current is calculated by the digital input frequency conversion power analyzer,
It can obtain the parameters such as voltage effective value, current effective value, fundamental wave voltage, fundamental current, harmonic voltage, harmonic current, active power, fundamental wave power and harmonic power FR-A820-90K-1(FR-A820-04750-2-60) MITSUBISHI FR-A820-90K-1(FR-A820-04750-2-60) MITSUBISHI. Superior high efficiency IPM motor.
Output power: 22kw.

Rated speed: 1500r/min FR-A820-90K-1(FR-A820-04750-2-60) MITSUBISHI FR-A820-90K-1(FR-A820-04750-2-60).
Voltage level: 200V.
IPM motor MM-EFS series can not be used to run the power frequency power.
The total wiring length of the IPM mottor shall not exceed 100m MITSUBISHI FR-A820-90K-1(FR-A820-04750-2-60).
1 inverters can not connect multiple IPM motors at the same time. Image operation panel equipped with liquid crystal display.


...More relevant models >>>>
Related model