GX-OD1622 Digital I/O Terminal 3-tier Terminal Block Type OMRON GX-OD1622

Brand: OMRON
Name: Digital I/O Terminal 3-tier Terminal Block Type
Model: GX-OD1622
Input capacity: 16 points.
Rated current (ON current): 0.5 A/output,
4.0 A/common.
Internal I/O common: PNP.
Residual voltage: 1.2 V max.
(0.5 ADC, between each output,
terminal and the V terminal)
Leakage current: 0.1 mA max.
ON delay: 0.5 ms max.
OFF delay: 1.5 ms max.
Number of circuits per common:
8 points/common.
Output indicators: LED display (yellow).
Isolation method: Photocoupler isolation.
I/O power supply method: Supply by I/O power supply.
Output device supply current: 100 mA/point.
Unit power supply current consumption: 90 mA max.
(for 20.4 to 26.4-VDC power supply voltage)
I/O power supply current consumption: 5 mA max.
(for 20.4 to 26.4-VDC power supply voltage)
Weight: 370 g max.
Expansion functions: No.
Output handling for communications errors:
Select either hold or clear.
Short-circuit protection function: No.
A common terminal is provided for each contact.
It eliminate the needs for relay terminal blocks.
It is unnecessary to share the common terminal,
among multiple contacts.
Easy-to-find wiring locations.
Detachable screw terminal block facilitates the maintenance.
Input response time can be switched for high-speed processing.
Selectable node address setting methods: setting with rotary,
switch and with tool software.
When setting the nodes with rotary switch, setting is easy and,
node identification becomes possible for maintenance.

Name: System Units; Turnback Units.
Specifications: Right Turnback Unit,
(Mounts to the right side of Slice I/O Terminal.)
Standards: CE, UC1, L, N.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be reduced OMRON GX-OD1622.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction GX-OD1622
Seven-segment Display on the Gateway Unit,
helps to detect errors on site.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error. Specifications: I/O; PNP (input: - common,
output: + common); 8 inputs/8 outputs OMRON GX-OD1622.
I/O connections: Sensor connector.
Rated internal circuit power supply voltage:
Supplied from the communications connector.
Rated I/O power supply voltage:
Supplied from external source for outputs.
Includes Sensor Connector That Conforms to,
Industry Standards And Can Be Used to Connect.
Sensors with Pre-wired Cables without Using,
Special Tools OMRON GX-OD1622.
Equipped with the standard Smart Slave,
functions that provide powerful.
preventative maintenance and,
troubleshooting capabilities.
Digital I/O Terminal compatible with,
industry-standard sensor connectors GX-OD1622 OMRON.
Connect sensors easily without special tools.
Reduce time required for wiring.
Load short-circuit detection. Short/disconnection detection: Supported GX-OD1622 OMRON.
Specifications: Inputs, NPN (+ common), 16 points.
I/O connections: Clamp terminals.
Rated internal circuit power supply voltage:
Supplied from communications connector.
Rated I/O power supply voltage: 24 VDC.
Reduced Wiring and Labor on Factory Sites with Screw-less Terminal Wiring.
Screw-less structure eliminates tightening work GX-OD1622 OMRON.
Detachable terminal blocks for easier maintenance.
Single-step wiring by simply inserting pole terminals. Name: e-CON Connectors.
Specifications: Outputs; 16 outputs; NPN;
Without Short-circuit and,
Disconnected Line Detection.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cosst can be reduced GX-OD1622.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on sitee OMRON GX-OD1622.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error.


...More relevant models >>>>