LK166
Home >> Products >> OMRON >> Control equipments >> Timer / time switch >> Analog timer >> H3BA-X8HA AC110V OMRON H3BA-X8HA AC110V

H3BA-X8HA AC110V OMRON H3BA-X8HA AC110V

Brand: OMRON
Name: Solid-state Timer
Model: H3BA-X8HA AC110V
Control output: Time-limit SPDT and Instantaneous SPDT.
Supply voltage: 110 VAC (50/60 Hz).
Solid-state Timer with Single Time Range.
and Operating Mode.
Time range: H3BA-X8HA (0.05 s to 12 h),
H3BA-X8HB (0.3 s to 30 h),
H3BA-X8HC (0.6 s to 60 h).
Operating mode: ON-delay only.
Pin type: 8-pin only.

Type: H5CZ.
Time specifications: Timer Mode, A-2: Power ON Delay I,
b: Repeat cycle 1, E: Interval, Z: ON/OFF-duty-adjustable flicker,
Twin Timer Mode, toff: Flicker OFF Start 1, ton: Flicker ON Start 1.
Operating modes: Timer Mode A: Signal ON Delay I, A-1: Signal ON Delay II,
A-2: Power ON Delay I, A-3: Power ON Delay II, b: Repeat cycle 1,
b-1: Repeat cycle 2, d: Signal OFF Delay, E: Interval, F: Cumulative,
Z: ON/OFF-duty-adjustable flicker, S: Stopwatch, Twin Timer Mode,
toff: Flicker OFF Start 1, ton: Flicker ON Start 1,
toff-1: Flicker OFF Start 2, ton-1: Flicker ON Start 2 OMRON H3BA-X8HA AC110V H3BA-X8HA AC110V
External connections: 8-pin socket.
Inputs: None.
Outputs: Contact output (time-limit SPDT + instantaneous SPDT) Models with, instantaneous contact outputs OMRON H3BA-X8HA AC110V.
Supply voltage: 12 to 24 VDC/24 VAC.
Easy to Use and Easy to Read.
Basic Features.
Character height of 10 mm for better readability.
Operation is simplified by the Up/Down Keys for each digit on 4-digit.
Safety and Reliability.
Power supply circuit and input circuits are isolated for safety and reliability.
Set value limit function prevents unexpected operation of output devices OMRON H3BA-X8HA AC110V.
caused by setting mistakes.
Output counter function helps in managing the service life of the Timer or,
the load.
Other Features.
Models with instantaneous contact output.
Waterproof, dust-proof structure (UL508 Type 4X and IP66).
Key protection. Category: external supply 100mA DC5V type.
Input type: load sensor, mV input type.
Event input terminal 5 points (TIMING, S-TIM, HOLD, RESET, ZERO) is equipped with.
Communication: RS-485; NPN open collector (HH, H, PASS, L, LL).
96 (W) * 48 (H * 95mm) depth.
Power supplly voltage: AC/DC24V H3BA-X8HA AC110V.
To support the sensor input, the pressure, load, torque and weight were measured,
Is an ideal indicator for judging whether an automatic device and a screening device are qualified.
Action determine the coloor, can switch the green / Red 2 kinds of color display H3BA-X8HA AC110V.
Equipped with the sub pressure gauge for monitoring the operation trend.
External event input