LK166
Home >> Products >> OMRON >> Control equipments >> Timer / time switch >> Analog timer >> H3CR-A8-301 OMRON H3CR-A8-301

H3CR-A8-301 OMRON H3CR-A8-301

Brand: OMRON
Name: Solid-state Timer
Model: H3CR-A8-301
Output: Contact.
Supply voltage: 100 to 240 VAC (50/60 Hz)/100 to 125 VDC;
24 to 48 VAC (50/60 Hz)/12 to 48 VDC.
Input type: No-input available.
Time range: 0.1 s to 600 h.
Operating mode(See note 2): Five multi-modes: A, B,B2, E, J (Power supply start).
Output: Transistor(Photocoupler).
Supply voltage: 24 to 48 VAC (50/60 Hz)/12 to 48 VDC.
Input type: No-voltage input.
Time range: 0.05 s to 300 h.
Operating mode (See note 2): Eight multi-modes: A, B, B2, C, D, E, G, J.
Multiple Operating Modes and Multiple Time.
Ranges. DIN 48 x 48-mm Multifunctional Timer.
A wide AC/DC power supply range greatly reduces the number,
of timer models kept in stock.
A wide range of applications with multiple operating modes,
eight modes for 11-pin models and five modes for 8-pin models.
Ecological design with reduced current consumption.
Easy sequence checking with instantaneous outputs for a zero set value.
Length of 75 mm or less when panel-mounted with a P3G-08,
Socket (H3CR-A8E, 100 to 240 VAC, 100 to 125 VDC),
PNP input models available.
Standards: UL, CSA, NK, LR, CCC, EN 61812-1, and CE Marking.

Supply voltage: 24 VDC.
Input type: DC voltage, DC current, or NPN input.
Output type: Judgement output, 2 relay contact outputs (SPST-NO) Normally energized relays (See note.);
Data transmission output, RS-485.
1/32 DIN Digital Panel Meter for Downsizing.
Equipment and Control Panels.
Compact size: 48 x 24 x 82 (W x H x D) OMRON H3CR-A8-301.
Multi-input compatible: DC voltage/current, rotary pulse H3CR-A8-301
Two display colors (switchable): green/red.
Selectable outputs.
CE marking and UL/CSA approval.
Splash-proof construction (NEMA4X: equivalent to IP66). Category: external supply 100mA DC5V type.
Input type: load sensor, mV input type.
Event input terminal 5 points (TIMING, S-TIM, HOLD, RESET, ZERO) is equipped with OMRON H3CR-A8-301.
Communication: RS-485; NPN open collector (HH, H, PASS, L, LL).
96 (W) * 48 (H * 95mm) depth.
Power supply voltage: AC100 ~ 240V.
To support the sensor input, the pressure, load, torque and weight were measured,
Is an ideal indicator for judging whether an automatic device and a screening device are qualified.
Action determine the color, can switch the green / Red 2 kinds of color display OMRON H3CR-A8-301.
Equipped with the sub pressure gauge for monitoring the operation trend.
External eventsInput type: NPN/ voltage pulse input type.
Event input terminal 5 points (HOLD, RESET) equipped with.
External power supply DC12V80mA.
Note: K3HB-RPB-A, K3HB-RNB-A is not equipped with event input.
DeviceNet; DeviceNet:--.
96 (W) * 48 (H * 95mm) depth.
Power supply voltage: AC100 ~ 240V.
Measurement of 2 points through the speed, time, or cycle of the digital time interval table.
Action determine the color, can switch the green / Red 2 kinds of color display.
Measurement of wide range of pulse interval time.
Measuring, calculating and displaying the pulse interval between 2 points.
Pulse interval measurement range, the maximum can be measured from 10ms to 3Unit: CPU Units.
Name: LED type without display (See note 1.).
No. of I/O points: 20.
LCD display: NO.
Power supply voltage: 12 to 24 VDC.
Inputs: 12, 12 to 24 VDC.
Outputs: 8, Relays.
Buttons, calendar, and clock: NO.
Analog input: Yes.
Even Broader Applications with Increased.
Functionality and Higher Precision.
Increased functionality in a compact body (70 mm wide × 90 mm high).
Easy programming is available using the LCD and operation,
buttons. (See note 1.).
This single Unit easily provides relay, timer, counter, and time,
switch functions.
Expansion is easy with Expanssion I/O Units, allowing up to 44,
I/O points H3CR-A8-301. (See note 2.).
Economy-type and Communications-type CPU Units have been,
added to series.
Improved Weekly Timers (See note 1.).
Increased timing accuracy with a monthly deviation of ±155 s,
max H3CR-A8-301. Multiple-day operation and pulse output operation have,
been added.
Select from two power supply options:
100 to 240 VAC or 12 to 24 VDC.


...More relevant models >>>>