LD77MH16 MITSUBISHI Positioning module

Brand: MITSUBISHI
Name: Positioning module
Model: LD77MH16

Differential output.
Axis of control: 4.
Maximum output pulse: pulse/s 4M.
Location data: 600 data / axis.
Max link distance: 10m.
Start is also simple.
Digital oscilloscope function.
Data collection and data collection in a simple motion controller that is synchronized with the control period.
Waveform display, you can improve the efficiency of the start LD77MH16 MITSUBISHI.
The use of steps in accordance with the auxiliary function can be LD77MH16
Can be set by different uses of the probe, easy to view the data set.
Can be on the word 16CH, bit 16CH data sampling.
Among them, the word 8CH, bit 8CH data can be displayed in real time.
Monitoring and testing function
Through a wealth of monitoring and testing functions, you can simply start and action check LD77MH16 MITSUBISHI.
Can only choose the necessary items from the rich monitoring information and monitor the display.
Through the test function, do not have to control procedures can also be implemented to confirm the basic action. Can be isolated to obtain DC24/48/100V, AC100/200V input signal.Can be isolated from the output of the programmable controller, the a/b/c contact relay, SSR, Tr output LD77MH16 MITSUBISHI. Number of input channels: 2Ch.
Input voltage: DC - 10 ~ 10V.
Input current: DC0 ~ 20mA.
Conversion speed: 80 s/ch.
Resolution: 1/12000.
Output channel number: 2Ch.
Output voltage: DC - 10 ~ 10V.
Output current: DC0 ~ 20mA.
Conversion speed: 80 s/ch.
Resolution: 1/12000.
Status of connected devices by means of alarm monitoring.
Alarm output function
Process alarm.
When the digital value is in the range of preset, the output alarm.
Change rate alarm.
The output value of the output value of the digital output is too large (greater than the rate of change of the alarm limit) or too small (less than the rate of change), the output alarm.
Achieve stability measurement
Inter channel isolation
Isolation between the channels, can prevent the connection of sensors in the channel between the cross talk, so as to achieve stable measurement.
High speed, smooth continuous analog output LD77MH16.
Waveform output function
Equipped with the industry''s first waveform output function.
The pre prepared waveform data can be imported into the analog output module, and the function of the analog output is simulatted according to the set conversion period LD77MH16.
It is not affected by the sequential scan time, and it can realize the high speed and smooth analog output.