LG2-AB AC110 OMRON LG2-AB AC110

Brand: OMRON
Name: Voltage Sensor
Model: LG2-AB AC110
Detected voltage: AC.
Compact, Economical Plug-in Type Voltage.
Sensing Relay.
DPDT output contacts expand the application of the Sensor to,
wide-ranging fields including control, alarms, and indication.
Voltage control is possible in the same easy manner as electro,
magnetic relays, as the output relay of the sensor can be driven,
directly with a detection signal.
Wide voltage setting range with fine setting capability.

Rated input voltage: 3-phase 3-wire mode, 380, 400, 415, or 480 VAC .
Ideal for Monitoring 3-phase Power Supplies.
for Industrial Facilities and Equipment.
Greater resistance to inverter noise.
Monitor undervoltages, overvoltages, voltage asymmetry, phase,
sequence, and phase loss in three-phase three-wire circuits with one unit OMRON LG2-AB AC110 .
One SPDT output relay, 5 A at 250 VAC (resistive load) LG2-AB AC110
World-wide power specifications supported by one unit.
(Set with a rotary switch.).
Relay status can be monitored using LED indicator. Time specification: Inverse type.
Current setting range: 50 to 160 A.
Operating voltage: 200/220/240 VAC.
Resetting method: Manual.
Solid-state Relay Enables Choice of Three OMRON LG2-AB AC110 .
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase.
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
is indicated from the start of operation OMRON LG2-AB AC110 .
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, and load conditions. Error will occur in the operating,
values of the overload elements. It is recommended to test operation, Sensor type and wiring: 2-wire DC 1-4/without polarity 3-4.
Actuator wiring: --.
No. of ports: 4.
No. of I/O: 4.
Simple Wiring of Sensor Actuators.
Greatly reduce wwiring in combination with the Smartclick XS5 LG2-AB AC110 .
Insert the connector and turn 1/8 of a turn to lock the connectors.
Higher rated current to enable output applications.
Use previous M12 screw connectors. Cable type: Standard Cables.

Type: Cable with Plugs on Both Ends (RJ45/RJ45) LG2-AB AC110 .
Cable length: 15 m.
Cables and Connectors for,
EtherCAT® and Other Industrial,
Ethernet Networks.


...More relevant models >>>>