LK166
Home >> Products >> MITSUBISHI >> R series PLC >> Substrate module >> MITSUBISHI R38B Main base plate

MITSUBISHI R38B Main base plate

Brand: MITSUBISHI
Name: Main base plate
Model: R38B
The input and output module installation number: 8.
DIN guide rail mounting adapter type: R6DIN1.
Size (H) * (32.5mm) * (W) * (D): * 328mm * 101mm. "

Output points: 32 points.
Output form: Transistor (source) output.
Rated open and close voltage, current: -.
Rated load voltage: DC12 ~ 24V.
Max load current: 0.1A/ point.
Response time: 1ms.
Common way: 32 point / public end.
Protection function (overload, overheat).
External wiring connection mode: 40 pin connector MITSUBISHI R38B.
Output module with mechanical relay contact mechanism,
Including the load voltage range of the relay and can be used for the output of the DC12~24V load transistor output type R38B
According to the load voltage, the output points of different, choose the most suitable user needs of the module.
Preventive maintenance based on the life of relay contact.
Relay output module can accumulate the number of ON of each output point MITSUBISHI R38B.
Through the understanding of the relay contacts of the number of times, according to the relay life of preventive maintenance. Analog input channel number: 4CH.
accuracy
Ambient temperature of 25 plus or minus 5 degrees C: plus or minus 0.1%.
Ambient temperature 0 ~ 55 degrees C: plus or minus 0.3%.
Temperature coefficient.
Common
Conversion speed: 80 s/CH MITSUBISHI R38B.
Channel to channel insulation.
Absolute maximum input: positive and negative 15V, 30mA.
External wiring connection mode: 18 point screw terminal.
Voltage input
The analog input voltage: DC - 10 - 10V.
Digital output value: 32000 ~ 32000.
Current input
Analog input current: DC0 ~ 20mA.
Digital output value: 0 ~ 32000.
16 bit high resolution (1/32000).
No program can perform scaling and conversion operations.
The most suitable for the requirements of speed and accuracy of the detection equipment.
Easy to filter high frequency interference.
Execute event driven programs via alarm output.
Through the engineering software, the output of arbitrary analog waveform data.
Channel insulation.
Similar to the input and output modules, analog quantity module is the interface between the sensor and the programmmable controller R38B.
The difference between the input and output modules is that it is dealing with analog voltage and current signals rather than ON/OFF signals.
The analog module MELSEC iQ-R series is equipped with high-speed conversion (80 s/CCH), high resolution (1/32000), channel insulation, abnormal signal detection and other convenient features,
Can achieve high precision analog control R38B.


...More relevant models >>>>