LK166
Home >> Products >> OMRON >> Power/other peripheral devices >> Power Supply >> Switching power >> S8FS-C35012 OMRON Switch Mode Power Supply

S8FS-C35012 OMRON Switch Mode Power Supply

Brand: OMRON
Name: Switch Mode Power Supply
Model: S8FS-C35012
Power rating: 350 W.
Input voltage: 100 to 120 VAC, 200 to 240 VAC (allowable range: 90 to 132 VAC,
180 to 264 VAC, or 254 to 373 VDC(Select with the switch.)*2).
Output voltage: 12 V VDC.
Output current: 29 A.
Built-in fan: Yes.
Model with terminal block facing upward.
High Reliability at a Reasonable Cost.
Reliable, Basic Power Supplies That,
Contribute to Stable Equipment Operation.
High Reliability: Enhanced abnormal overvoltage,
resistance and lightning surge resistance for stable,
operation even with an unstable input voltage.
Long Life: Japanese 105°C electrolytic capacitors are used,
to achieve stable quality and long life. A reliable 3-year warranty.
Wide Input Ranges: 100 to 120 VAC and 200 to 240 VAC,
Full Lineup: Models are available for the main output,
voltages and capacities used in FA applications.
Global Standards: Conforms to CE (all models),
Approved for UL (all models) and CCC (15 to 150-W models).
Easy mounting to DIN Rails with Mounting Brackets (sold separately).
Refer to Period and Terms of W.

Power ratings: 90 W.
Input voltage: 100 to 240 VAC(allowable range: 85 to 264 VAC or 80 to 370 VDC*1).
Output voltage: 24 V.
Output current: 3.75 A.
Alarm output *2: Sourcing.
UL Class 2 Output standards: Yes.
Model number(screw terminal block).
60/90/120/180/240/480-W Models.
New Models with Indication S8FS-C35012 OMRON.
Monitor and Simple Functions for.
Easy System Commissioning.
New 90-W models with indication monitor that S8FS-C35012
conform to UL Class 2 Output standards.
New models with screwless terminal blocks and,
indication monitor.
Status displayed on 3-digit, 7-segment display.
Safety standards: UL 508/60950-1,
CSA C22.2 No. 107.1/60950-1,
EN 50178 (= VDE 0160), EN 60950-1 (= VDE 0805 Teil 1) S8FS-C35012 OMRON.
Input conditions: DC input is also possible from 80 to 370 VDC.
(Not compliant with EC Directives and other safety standards.) Function: Phase sequence, phase loss, and temperature monitoring.
Power supply voltage: 100 to 240 VAC.
Monitor Temperature Rise through.
Internal Motor Loss.
Temperature, phase sequence, and phase loss monitoring with,
the DIN 22.5-mm-sized K8AK-PT Relays S8FS-C35012 OMRON.
Side-by-side mounting of K8AK-PT Relays.
Specially designed for internal motor monitoring; no setting required.
Test/Reset Button for confirmation of output operation.
Monitoring also performed for thermistor disconnections and short circuits.
Manual or automatic resetting with the same Relay. Model: P2RF (front-mounting), page 9.
Approx: 33 g.
Number of pins: 8 pins.
A Wide Variety of Square and,
Round Sockets in Front-mounting,
and Back-mounting Models,
Models available with finger protection.
Hold-down Clips and Socket Bridges for PYF Sockets,
are also available.
New screwless models available. Time specification: Inverse type.
Current setting range: 2 to 8 A.
Operating voltage: 200/220/240 VAC.
Resetting method: Manual.
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase.
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
is iindicated from the start of operation S8FS-C35012.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, and load conditions S8FS-C35012. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
before using the K2CM.


...More relevant models >>>>