LK166
Home >> Download >> MITSUBISHI >> Manual Download >> MITSUBISHI L02SCPU-P Programming Manual (Special Instructions) PDF

MITSUBISHI L02SCPU-P Programming Manual (Special Instructions) PDF

Brand: MITSUBISHI
Product model: L02SCPU-P
Name: PLC
Sort: Programming Manual (Special Instructions)
File language: English
File size: 7.81MB
Output channel number: 4ch.
Output voltage: DC - 10 ~ 10V.
Output current: DC0 ~ 20mA.
Conversion speed: 20 s/ch.
Resolution: 1/20000.
Status of connected devices by means of alarm monitoring L02SCPU-P PDF.
Alarm output function
Process alarm.
When the digital value is in the range of preset, the output alarm.
Change rate alarm.
The output value of the output value of the digital output is too large (greater than the rate of change of the alarm limit) or too small (less than the rate of change), the output alarm L02SCPU-P
Achieve stability measurement
Inter channel isolation
Isolation between the channels, can prevent the connection of sensors in the channel between the cross talk, so as to achieve stable measurement L02SCPU-P PDF.
High speed, smooth continuous analog output.
Waveform output function
Equipped with the industry''s first waveform output function.
The pre prepared waveform data can be imported into the analog output module, and the functioon of the analog output is simulated according to the set conversion period L02SCPU-P PDF L02SCPU-P Manual.
It is not affected by the sequential scan time, and it can realize the high speed and smooth analog output. "Universal output function: source type.
Program capacity: 260K step.
Basic operations processing speed: 9 MITSUBISHI Programming Manual. 5ns.
Communication interface: USB/Ethernet (built-in CC-Link function).
Program capacity: 20K step.
Control mode: stored procedure repeated operation.
Input / output points: 4096 points.
End cap.
High precision PWM control of the highest 200kHz.
In the PWM output mode, by setting the ON time and cycle time,
The duty cycle can be changed, and the minimum cycle time is 5 s MITSUBISHI Programming Manual.
In addition to lighting dimming control, simple motor control and heater control,
Can also be used to require high resolution detection equipment, such as a wide range of oscillators.
CPU built-in functions can be easily set through programming tools MITSUBISHI Programming Manual.
The built-in I/O function settings can be easily carried out through the parameters of the prrogramming tool L02SCPU-P Programming Manual.
5 s units can be used for high precision workpiece measurement in pulse measurement mode,
Can be used with a minimum of 5 s units of the input signal of the ON/OFF time (the shortest 200 s) for high precision measurrement L02SCPU-P Manual.
For example, after measuring the ON time of the sensor input,
The "moving speed" and "length" of the workpiece can be accurately calculated ". "
Related products
MITSUBISHI
cpu module
L06CPU-P
MITSUBISHI cpu module L06CPU-P
"Universal output function: source type. Prog
MITSUBISHI
cpu module
L26CPU-PBT
MITSUBISHI cpu module L26CPU-PBT
"Universal output function: source type. Prog
MITSUBISHI
cpu module
L02SCPU-P
MITSUBISHI cpu module L02SCPU-P
"Universal output function: source type. Prog
MITSUBISHI
cpu module
L02SCPU-CM
MITSUBISHI cpu module L02SCPU-CM
"Universal output function: leakage type. Pro