LK166
Home >> Download >> MITSUBISHI >> Manual Download >> MITSUBISHI L06CPU-CM Programming Manual (Special Instructions) PDF

MITSUBISHI L06CPU-CM Programming Manual (Special Instructions) PDF

Brand: MITSUBISHI
Product model: L06CPU-CM
Name: PLC
Sort: Programming Manual (Special Instructions)
File language: English
File size: 7.81MB
Output channel number: 4ch.
Output voltage: DC - 10 ~ 10V.
Output current: DC0 ~ 20mA.
Conversion speed: 20 s/ch.
Resolution: 1/20000.
Status of connected devices by means of alarm monitoring L06CPU-CM PDF.
Alarm output function
Process alarm.
When the digital value is in the range of preset, the output alarm.
Change rate alarm.
The output value of the output value of the digital output is too large (greater than the rate of change of the alarm limit) or too small (less than the rate of change), the output alarm L06CPU-CM
Achieve stability measurement
Inter channel isolation
Isolation between the channels, can prevent the connection of sensors in the channel between the cross talk, so as to achieve stable measurement L06CPU-CM PDF.
High speed, smooth continuous analog output.
Waveform output function
Equipped with the industry''s first waveform output function.
The pre prepared waveform data can be imported into the analog output module, and the function of the analog output is simulated according to the set conversion period L06CPU-CM PDF.
It is not affected by the sequential scan time, and it can realize the high speed and smooth analog output. Thermocouple input.
Number of input channels: 4ch.
Standard control.
Heating and cooling control MITSUBISHI Programming Manual.
Self tunning function L06CPU-CM Manual.
Peak current suppression.
Heating function at the same time.
Sampling period switching function.
Temperature input mode.
Temperature regulation mode.
To achieve high stability temperature control
Standard control / heating, cooling control.
The device used for the temperature control of the temperature control of the extrusion molding machine can prevent over heating and cooling MITSUBISHI Programming Manual.
According to the object device can choose any one of the following control method.
Standard control (heating or cooling).
Heating, cooling control (heating and cooling).
Hybrid control (combination of standard control and heating, cooling control) MITSUBISHI Programming Manual.
To reduce operating costs by saving energy
Peak current suppression
After the peak current suppression function is used, the number of the upper limit output limit of each channel can be changed automatically,
Split transistor output time. To suppress the peak current.
Restrain the peak current to achieve energy saving effect (reducing the power supply capacity of the equipment, saving the electricity contraact), and reduce the operation cost L06CPU-CM Programming Manual.
Achieve average temperature control
Warming function at the same time
By making the arrival time of the multi loop consistent, uniform temperature control function.
It can control temperature uniiform, to ensure that the control object no local burning or thermal expansion L06CPU-CM Manual.
No idle running, with energy saving effect, can reduce operating costs.
Related products
MITSUBISHI
cpu module
L02SCPU-CM
MITSUBISHI cpu module L02SCPU-CM
"Universal output function: leakage type. Pro
MITSUBISHI
cpu module
L06CPU-CM
MITSUBISHI cpu module L06CPU-CM
"Universal output function: leakage type. Pro
MITSUBISHI
cpu module
L26CPU-CM
MITSUBISHI cpu module L26CPU-CM
"Universal output function: leakage type. Pro
MITSUBISHI
cpu module
L06CPU-P
MITSUBISHI cpu module L06CPU-P
"Universal output function: source type. Prog