Three-phase 4 wire type.
Measuring circuit number: 3 circuits.
Measurement items: power consumption (consumption, regeneration), current, voltage, power, power factor, etc Q26UDEHCPU PDF. .
Power measurement module product group capable of simply measuring various energy information.
With only one module can be used to measure and power consumption (consumption and regeneration), reactive power, current, voltage, power, power factor and frequency of all kinds of detailed information Q26UDEHCPU
No ladder program can continue to monitor the minimum and maximum values, can also perform 2 types of upper / lower limit alarm Q26UDEHCPU PDF.
Only in the ON state can be used to measure the output of the output device.
Therefore, the amount of electricity and the quantity of electricity in the unit of the beat can be obtained during the operation of the equipment.
3 phase 3 wire products can be used to measure up to 4 circuits in one slot,
3 phase 4 wire products can be used to measure up to 3 circuits,
So the electrical energy measurement can be carried out in a small space by the multi circuit products Q26UDEHCPU PDF.
For example, a module can be used to measure other loads frrom the control panel trunk Q26UDEHCPU Manual .
In addition, Works2 GX (version 1.90U and higher) can be used to easily set parameters MITSUBISHI Programming Manual. Input points: 8 points (dual input), 16 points (single input).
Isolation mode: photoelectric coupling.
Rated input voltage: DC24V.
Output points: 4 points (select the source type + drain type), 2 points (when selecting the source type + source).
Isolation mode: photoelectric coupling MITSUBISHI Programming Manual.
Rated input voltage: DC24V.
Security PLC (secure programmable system) refers to the self or external components or the implementation of the failure of the agency,
Can still respond to and promptly cut off the output of the programmable system.
Different from ordinary PLC, security PLC not only can provide the function of ordinary PLC,
Safe control function can be realized,
Meet the requirements of the ISO 13849-1 EN and IEC 61508 control system safety related component standards MITSUBISHI Programming Manual.
PLC security market mainstream has oilz (Pilz) PSS 3000, PSS 4000,
PSS 4000 in addition to the security process can also be processed outsidee the standard control procedures Q26UDEHCPU Programming Manual.
All the components in the security PLC adopt the redundancy structure,
Two processor processing for cross detection,
The processing results of each processor are stored in their respective memoryy,
Output is only when the processing result is in full agreement,
If any inconsistency occurs during the process, the system is immediately shut down Q26UDEHCPU Manual .
Related products
MITSUBISHI
With Ethernet CPU
Q50UDEHCPU
MITSUBISHI With Ethernet CPU Q50UDEHCPU
Input / output points: 4096 points. Numer of
MITSUBISHI
With Ethernet CPU
Q06UDEHCPU
MITSUBISHI With Ethernet CPU Q06UDEHCPU
Input / output points: 4096 points. Numer of
MITSUBISHI
With Ethernet CPU
Q13UDEHCPU
MITSUBISHI With Ethernet CPU Q13UDEHCPU
Input / output points: 4096 points. Numer of
MITSUBISHI
With Ethernet CPU
Q20UDEHCPU
MITSUBISHI With Ethernet CPU Q20UDEHCPU
Input / output points: 4096 points. Numer of