Program memory capacity: 8k.
Input / output points: maximum 256 points.
A scan cycle of PLC must pass through three stages: input sampling, program execution and output refresh.
PLC in the input sampling phase: first of all, in order to scan the sequence of all existing input latches in the input terminal of the state or input data read,
And write it into the corresponding input status register,
Refresh the input, then close the input port, enter the program execution stage AJ71QE71N-B5T PDF AJ71QE71N-B5T The A1SP60 pulse capture module is a 16 point DC24V input module,
Can be used as a general input module,
Can also be used as a pulse capture module,
Pulse capture function makes the input signal width in the sequence can be as short as 0 AJ71QE71N-B5T PDF. 5ms,
Once there is a pulse signal input, the state is memory,
A1SP60 to ensure that the control process at least once again to control the state of the memory of the operation,
Input can be set to 4 blocks,
Each block can be set to a general function or pulse capture function. Output type: transistor output, drain type.
Output points: 8 points.
OFF leakage current: 0.1mA.
Output protection function AJ71QE71N-B5T PDF.
Rated load voltage / current: DC24V/DC24V/0.1A.
External connection: 2 wire.
Fast connector type.
Simple wiring through quick connector.
Can be installed along the 6 direction.
MITSUBISHI PLC program simulation debugging
The basic idea of program simulation debugging is,
In order to facilitate the form of simulation to generate the actual state of the scene,
Create the necessary environmental conditions for the operation of the program.
Depending on the way the field signals are generated,
The simulation debugging has two forms of hardware simulation and software simulation. Cable length: 3 meters.
Connection between FX1N-232-BD and FXCPU for GOT expansion board. Cable length: 5 meters.
Long distance CPU extension cable.
For QnA/ACPU/ motion control and GOT connecttion AJ71QE71N-B5T datasheet. Output type: relay output.
Output points: 32 points.
OFF leakage current: -.
Output protection function: No.
Rated load voltage / current: DC24V/AC240V/2A.
External connection: 1 wire.
A2C shape terminal.
Type of input and output terminal AJ71QE71N-B5T datasheet.
Shape and A2C input and output modules are identical (same mounting dimensions),
Machining and installing holes are not required.
Related products
MITSUBISHI
Ethernet module
AJ71QE71N-B5T
MITSUBISHI Ethernet module AJ71QE71N-B5T
Ethernet network module 10BASE-T/10BASE5 Equi
MITSUBISHI
Ethernet module
AJ71QE71N-B5
MITSUBISHI Ethernet module AJ71QE71N-B5
10BASE5. For Q mode. Control layer /MELSECNET
MITSUBISHI
Ethernet module
AJ71QE71-B5
MITSUBISHI Ethernet module AJ71QE71-B5
Ethernet network module 10BASE5 Control layer
MITSUBISHI
Network module
AJ71QE71N3-T
MITSUBISHI Network module AJ71QE71N3-T
10BASE-T. For Q mode. When communicating in t